Ac capacitor yellow wire

The threat of Yellow Fever could be kept in check with a few simple steps Until the early 20th century large epidemics of yellow fever erupted routinely in Africa, Europe and the A...

Ac capacitor yellow wire. Standard Hampton bay ceiling fan without a remote has an easy and straightforward ceiling fan wiring diagram. The Hampton Bay ceiling fan wiring diagram starts with the power source. The black wire is the hot wire and leads to the switch. The white wire is the neutral or common wire and goes straight to the outlet box.

This image shows the structure of an AC induction motor, which is the most basic type of AC permanent split capacitor motors. The rotating element, the rotor, is supported in the motor case by 2 ball bearings for long life. The stator is located around the rotor with a thin air gap. The output shaft is connected to the rotor.

Mostly for new digital thermostats that require continuous power via C-wire. Typical 6-wire thermostats will use red (R or Rc or Rh), white (W, W1), yellow (Y, Y1), green (G), black or blue C-wire, and orange (O/B) wire for reversing valve switch; used for complex heat pumps. Thermostat wire color meanings are standardized.A capacitor stores and releases electrical energy during every cycle change. A run capacitor matches the system to create the ideal phase shift for optimal running efficiency and power usage by the motor. Contrary to what many people say, a capacitor does not "boost" the voltage or create extra energy. The capacitor only stores and releases ...The only thing missing from this graphic is the motor rotation wiring which is a yellow and a purple wire that will reverse the direction of the motor depending on what direction is needed. Some are clockwise, and some are counter-clockwise. ... Wiring an Air Conditioner Condenser Run Capacitor Compared to a Heat Pump Condenser Run Capacitor ...AC ALTERNATIVES® INCOME FUND I CLASS- Performance charts including intraday, historical charts and prices and keydata. Indices Commodities Currencies StocksOk, easy enough. But then with that connected, I have 2 unconnected black wires. Does the black from the capacitor connect to the 2 black wires in the fan cup? Lastly, there is an unconnected yellow wire coming out of the fan cup. Kind of at a loss with this one. Pic included of my capacitor. (black on one side, yellow, red, blue on the other)

red - goes to contactor common. yellow - goes to compressor start winding (make sure this wire runs inside the unit) if this is correct the new one should be connected as follows. red to common terminal capacitor. purple to common terminal capacitor. brown to fan terminal capacitor.Window AC Wiring With Combined Capacitor ! How Do You Wire A Dual Capacitor ! Window AC ConnectionHi Friends,I am Ismail Khan and all of you are most welcome...Proper AC service can determine the root of the issue before any other steps are taken. 2. Humming Noise from Outdoor Unit. A sure sign of a bad AC capacitor is a humming sound from within the access panel. Any humming noises indicate a problem with the air conditioning system or the components of the AC unit.Attach the Yellow wire to the Y terminal for AC/cooling mode. 4). Attach the Green wire to the G terminal for the Fan. 5). Attach a “spare” wire to the C terminal – such as the Black wire for C or Common. 6). Attach the …They are also used in certain amplifier and signal conditioning circuits because capacitors easily pass higher frequency AC signals but they block DC (constant) signals. ... (yellow 6.3V, black 10V, green 16V, blue 20V, grey 25V, white 30V, pink 35V). ... but wire-ended capacitors are ok, providing the device leads are no longer than 1.5 mm ... The condenser fan motors in both are essentially the same, except for how they are controlled. That means they will be wired differently in the condenser. The wiring for the AC condenser fan motor will likely have the black wire (noted in the wiring diagram) go directly to the compressor contactor. Furthermore, the heat pump condenser fan motor ...

This image shows the structure of an AC induction motor, which is the most basic type of AC permanent split capacitor motors. The rotating element, the rotor, is supported in the motor case by 2 ball bearings for long life. The stator is located around the rotor with a thin air gap. The output shaft is connected to the rotor.A dual round capacitor shares the common leg while the other two leads are for the FAN and Compressor. When swapped out for two single capacitors a jumper is added to add another common lead. Both …On the capacitor, the yellow wire is connected to the yellow, and the same for orange.. motor; h-bridge; wiring; ... Just as a thought, one side of the AC line is attached directly to the motor. Perhaps putting the other AC lead to one side of the capacitor will make it run one direction and switching to the other side of the capacitor for the ...I have a Bryant Coastal unit that had a cap replaced under a year ago. The unit failed again. I was told that the cap was o.k. but that the wires to it had melted and thus the cap had to be replaced. They theorized that it may have been due to a surge. The electrical service has a Leviton whole house surge protector that is showing green. I'm …In summary, the conversation is discussing the use of capacitor terminals and their designations, specifically in regards to AC circuits.Product Description. This sale is for a CBB61 Fan Motor Run Capacitor. With the following specifications: Capacitance: 15 uF Voltage: 250V AC Case: 47 mm L x 33 mm H x 20 mm W. This low dissipation, stable capacitance and good self-healing performance capacitor is widely used for drought fan, fan, dehumidifier... etc. electrical appliances and ...

Labcorp encinitas appointment.

i was able to turn my ac fan by hand and it slowly picked up needless to say pump wouldn't turn on due to no jolt of energy due to bad capacitor...CBB61 4.5uf + 5uf + 6uf 4-Wire 250V AC Ceiling Fan Capacitor by BlueStars - Pack of 1 - Replacement for Hampton Bay Ceiling Fan - 50/60 Hz - 4 Wires Electrical Power Relay Connecting Capacitor. ... New 5 Wire Ceiling Fan Capacitor Replacement for New Tech CBB61 250VAC 50/60 Hz 4.5uf+6uf+5uf 2Pcs.Standard Hampton bay ceiling fan without a remote has an easy and straightforward ceiling fan wiring diagram. The Hampton Bay ceiling fan wiring diagram starts with the power source. The black wire is the hot wire and leads to the switch. The white wire is the neutral or common wire and goes straight to the outlet box.Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit.

I don't understand the direction of current flow when a capacitor is wired in series with the start windings in, say, a fridge or other AC motor running at/under 120V AC. Wiring diagrams seem to suggest that voltage energizes the hot leg of the circuit and current flows through the run windings and then returns via the neutral leg.uxcell Ceiling Fan Capacitor CBB61 5uF 350V AC 2 Wires Metallized Polypropylene Film Capacitor 47x34x22mm for Electric Fan Pump Motor Generator 4.3 out of 5 stars 29 2 offers from $7.59motor-run capacitor. Connect the (black) wire from the common on the TES5 to the CPT® Connect the wire from the fan motor to the green terminal. Connect the (white) wire from the potential relay on the TES5 to the herm side of your motor-run capacitor. Connect one wire from the motor to one terminal on the capacitor and connect the other wire ...An AC capacitor (or aircon capacitor) is just like any other capacitor we've been talking about, that stores charge and delivers electricity to start/run the motor when …It is marked 250WV.AC, says SK Taiwan, and has 4 wires (2 are yellow, one is gray, and one is pink). On the drawing on the side of the capacitor, for the yellow wire to the pink wire it says 4 microfarads, and for the yellow wire to the gray wire it says 5 microfarads. Also, twice it mentions 1/2 W 330K.Once the power is disconnected and the terminals are identified, it is time to connect the start capacitor to the motor. Start by connecting one end of a wire to the Common terminal on the capacitor. 4. Connect the Other End of the Wire. Take the other end of the wire and connect it to one of the terminals on the motor.Capacitor Burn-Out. High heat levels will cause capacitors to begin to lose their ability to store an electrical charge. As a capacitor begins to fail, it will create clicking noises. This is the major warning sign that you need to call on repair technicians to remedy the problem. Another warning sign is when the air conditioner begins to ...In an air conditioning (AC) unit, a dual capacitor is a crucial component used to start and run the compressor and the fan motor. It combines two capacitors ...

1. Looks like this is what you have there. As long as you have the capacitor in series with at least one motor winding, you should damage anything. If you look at the top terminals on the capacitor, you should see that they make up a small terminal block on each side.

A 1-farad capacitor can store one coulomb (coo-lomb) of charge at 1 volt. A coulomb is 6.25e18 (6.25 * 10^18, or 6.25 billion billion) electrons. One amp represents a rate of electron flow of 1 coulomb of electrons per second, so a 1-farad capacitor can hold 1 amp-second of electrons at 1 volt. A 1-farad capacitor would typically be pretty big.THE 4 WIRES THAT HOOK ONTO THE CAPACITOR.RED.BLack yellow,and purple go where on the 3prong cap.it is labled - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... I have 3 wires for my Lenox HS24 air conditioning unit, I.The two capacitor paradox or capacitor paradox is a paradox, or counterintuitive thought experiment, in electric circuit theory. [1] [2] The thought experiment is usually described as follows: Two identical capacitors are connected in parallel with an open switch between them. One of the capacitors is charged with a voltage of , the other is ...Replacing an old AC unit or installing a new one can be a big — and pricey — job. Learn about AC installation costs with this comprehensive guide. Expert Advice On Improving Your H...A Quick Guide for Installing 4 Wire Condenser Fan Motors. (HVAC)Proper AC service can determine the root of the issue before any other steps are taken. 2. Humming Noise from Outdoor Unit. A sure sign of a bad AC capacitor is a humming sound from within the access panel. Any humming noises indicate a problem with the air conditioning system or the components of the AC unit.Help with Akai X-150D (motor capacitor) I have recently decided to replace the capacitor in my Akai and was stumped as to where I need to solder the wires on the new capacitor. The old one had markings for common ground and the red wire, but this Titan cap has no indicators. (The yellow wire with the cap as far as I know is only needed for 50 ...The air conditioner capacitor is a device that briefly stores electrical energy. It uses that energy in your air conditioner to help start and run the fan motor and compressor. (2) ... If you do not wish to wire in the free capacitor then we recommend replacing your dual capacitor when replacing your condenser fan motor and discarding …How to hook up an electric motor start or run capacitor: This article gives electric motor start-run capacitor installation & wiring instructions for electric motor capacitors designed to start & run an electric motor such as an AC compressor, heat pump compressor or a fan motor, and how to wire up a hard-starting air conditioner compressor motor, fan motor, to get an air conditioner, heat ...

Live pd tonight.

Truist morgantown pa.

US, AC:The US National Electrical Code only mandates white (or grey) for the neutral power conductor and bare copper, green, or green with yellow stripe for the protective ground.In principle any other colors except these may be used for the power conductors. The colors adopted as local practice are shown in Table below.. Black, red, and blue are used for 208 VAC three-phase; brown, orange and ...On 2016-06-22 by (mod) re: rheem heat pump air conditioner. CHeck for power at the leads. On 2016-06-22 by john. Have a rheem heatpump, air conditioner, replaced capacitor, wired. red wire to C; purple to HERM; orange to C; brown to FAN; won't come on, failed to write down before disconnecting. Is this right,could it be fuse? On 2016-05-28 by pat1. Full exterior shot. 2. Wires coming out of new fan motor. Yellow, Black, Brown, Brown Stripe. 3. New fan motor capacitor. Currently wired with brown and brown stripe wire from fan motor. You can also see the blue striped wire that I have attached to the cap.About this item. BRAND: JCM brand new fan capacitor CBB 61. SPECIFICATIONS: 2.5uF (MFD) 250Volts AC 2 Wire. Hertz: 50/60 Hz. STYLE: CBB61 Square black Capacitor. USAGE: Fan AC Capacitor for running the motor in Ceiling and Exhaust fans, air vents, and other electronic motors.An AC capacitor (or aircon capacitor) is just like any other capacitor we've been talking about, that stores charge and delivers electricity to start/run the motor when … 3 in 1 Start Capacitor Wiring Diagram. The 3 in 1 capacitor has 5 wires: White: it is connected to the starting terminal of the compressor. Black: This wire is connected to the common terminal on the compressor. Red: it connects to the run terminal of the compressor. L1: This wire is linked to the line voltage wire. W-wire - white wire. this wire goes to the gas controls to engage the heat on a call for heat from the thermostat when you have it set to heating mode. This closes the 24-volt control side of the gas furnace and begins the process of starting the gas furnace into its sequence of operation. Y-wire - yellow wire typical color.Replacing an AC condenser costs between $1,900 and $4,375. But is AC condenser replacement worth it, or should you replace your entire AC system? Expert Advice On Improving Your Ho...Your motor has 3 wires (Common, Start, and Run). The run cap connects to Start and Run. With 4 wire motors the brown wire with a white strip is also connected to the motor Run leg. Upvote. # 3. 11-05-22, 02:59 PM. R.Air Conditioning (AC) Tune-Up, Repair, & Installation Services. If you are encountering a broken air conditioner capacitor in your system, give our team a call (703) 543-9649 to receive assistance. Our team of technicians offer exceptional air conditioning repair and air conditioning installation services for homeowners in Sterling and other ...PART 1: Wiring without a direction switch Identify the wire colors and confirm that the gearmotor or motor is a 3-wire reversible PSC model. Bodine stock motors have red, black, and blue motor leads and a green-yellow ground lead. How to Wire a Permanent Split Capacitor (PSC) 3-Wire Reversible AC Motor or Gearmotor (115VAC/60Hz Models) ….

To reverse rotation on a single phase capacitor start motor, you will need to reverse the polarity of the starter winding. This will cause the magnetic field to change directions, and the motor will follow. In order to achieve this, you can swap the connections on either end of the winding. Always reverse the wires that lead to the starter winding.Common AC Capacitor Wiring Colors. While wiring colors may vary depending on the manufacturer and model of your AC unit, there are some common color codes that are widely used. Here are the most frequently encountered AC capacitor wiring colors: Red: The red wire is typically connected to the “C” terminal of the capacitor, which stands for ...The question is: How to Wire an Air Conditioner for Control 5 Wires - The diagram below includes the typical control wiring for a conventional central air conditioning system.Furthermore, it includes a thermostat, a condenser, and an air handler with a heat source. Moreover, the heat source for a basic ac system can include heat strips for electric heat or even a hot water coil inside the ...Cheap Chinese made caps fail and build up heat. A female spade terminal that does not exert sufficient pressure while gripping the male spade terminal can also build up heat. A LOT of heat. When a wire's insulation is damaged, THAT is you heat source.My AC fan does not turn on but was working alittle while ago,I opened up and looked at the capacitors,One duel and one single,The duel has 1 wire from hem and 2 wires coming from the common but no wires from the fan terminal.Thats not right.Can the single capacitor be running the fan and needing replace too.I am getting a reading 35.7 on the single and 5 on the duel withno reading when I touch ...Step 1: Identify the Wiring Connections on the AC Dual Capacitor. In order to properly wire an AC dual capacitor, it is important to first identify the wiring connections on the capacitor. The dual capacitor is designed to provide power to both the fan motor and the compressor of an air conditioning unit.Cheap Chinese made caps fail and build up heat. A female spade terminal that does not exert sufficient pressure while gripping the male spade terminal can also build up heat. A LOT of heat. When a wire's insulation is damaged, THAT is you heat source.CBB61 5uf 2-Wire 250V AC Ceiling Fan Capacitor by BlueStars - Pack of 1 - Electric Fan Pump Motor Generator - 50/60 Hz - 2 Wires Electrical Power Relay Connecting Capacitor. 4.8 out of 5 stars. 19. 100+ bought in past month. $7.99 $ 7. 99. Buy any 10, Get 1 free. Ac capacitor yellow wire, Sometimes its hard to find the right ratings of a dual run cap in your AC. Here is how i replaced a dual run capacitor with two capacitors. Here is a video o..., Wholesale Factory Price 3 Wire 450v Fan Capacitors For Ac Electric Motor Run , Find Complete Details about Wholesale Factory Price 3 Wire 450v Fan Capacitors For Ac Electric Motor Run,Table Fan Capacitor,Ac Ceiling Fan Capacitor,Circulating Fan Capacitor from Capacitors Supplier or Manufacturer-Lishui Topo Electronic Co., Ltd., Make sure it is oriented correctly with the terminals facing outward for easy access. 5. Connect the wires to the new capacitor: Referencing your notes from step 3, connect each wire to the corresponding terminal on the new dual capacitor. Double-check your connections to ensure they are tight and secure. 6., In general, capacitor wires are designated by three colors: red for the power source's positive side, yellow for controlling the fan motor's speed, and white for the neutral side of the power source, which connects to the ground. ... In conclusion, understanding AC capacitor wiring colors is essential for any electrician or HVAC technician ..., The problem with single-phase electric motors is that they can't produce a rotating magnetic field on their own—that's where the capacitor comes in. The AC's capacitor creates a leading current in the motor's start winding. The leading current creates a rotating magnetic field that makes the motor start spinning., If you cannot locate the wiring diagram on your appliance, you can call the GE Appliances Answer Center to obtain one. You will need to have your complete model number. The diagram will be emailed. You can reach us by dialing 1-800-626-2005. We are available to handle your request Monday - Friday, 8:00 AM to 7:00 PM, EST, closed Saturday and ..., To complete wiring, connect the green-yellow ground lead to the ground wire in the AC line cord (Figure 7). To connect the motor to run counterclockwise:(see connection diagram 07410072) Connect the red wire from the motor and the hot lead from the AC line cord to one lead of the capacitor. Since the wiring diagram does not specify , Yes ( provided the capacitor is the proper microfarad and voltage ) , you can use a 2 terminal capacitor for the fan motor . Provided you wire it correctly . But , it is OK to use the common and fan terminals of the 3 terminal capacitor . For the fan motor & no wire to the herm terminal . God bless., Capacitor Color Codes for Identification Chart. Electronics, Instrumentation & Electrical Database . Capacitor Color Codes for Identification Chart. Capacitors may be marked with 4 or more colored bands or dots. The colors encode the first and second most significant digits of the value, and the third color the decimal multiplier in picofarads., Jul 24, 2022 · Hello, I am changing out the capacitor in my Goodman CE25-1EB air conditioner. The wires are different colors and configurations than I have found online. read more , Buy CBB61 5 Wire Ceiling Fan Capacitor for New TECH 5+5+5uf 50/60Hz 250VAC (3 pcs): Capacitors ... GAOHOU 5 Wire Ceiling Fan Capacitor CBB61 5+5+5uf 250V-300V AC 50/60 Hz Power Relay. $8.49 $ 8. 49. Get it as soon as Thursday, Apr 25. In Stock. Sold by SMTHOME and ships from Amazon Fulfillment. +, 43-23204-32 -Rheem OEM Round Replacement Dual Run Capacitor 55 + 3 UF/MFD 370 Volt: Hvac Controls: Amazon.com: Industrial & Scientific. This is the diagram I used to wire them for ccw rotation: [ATTACH=CONFIG]34107 [/ATTACH] Here"s how it looks now: Orange and Purple wires from the fan are connected to "Fan" on the capacitor., Incorrect installation and/or improper circuit application that subjects the capacitors to reverse bias may lead to performance degradation or catastrophic failure (short circuit) of the capacitor. Where does the yellow wire go on capacitor? Currently, AC is working fine right now. However, seen on other posts that Yellow = Herm and Blue = Common., Yes, the capacitor has gotten damaged, at least somewhat. How badly damaged, and how irreversible the damage depends on what voltage was applied for how long. A 50 V capacitor can probably take 5 V in reverse for a few seconds, and probably mostly recover when promptly forward biased. The prognosis gets worse at higher voltage and longer time., The polarity is differentiated as "+" which means an anode and "-" means cathode. If a voltage applied is greater than 1 or 1.5 V then the capacitor breaks downs. Are capacitors AC or DC? Capacitor comes in different shapes and their value is measured in farad (F). Capacitors are used in both AC and DC systems (We will discuss it below)., 11. Two wires do make a capacitor. Just a very small one. For parallel plates, capacitance can be calculated as: C = εA d C = ε A d. Where: ε ε is the permittivity of the dielectric, which is mostly air for some wires, with ε ≈ 8.85 ⋅10−12F/m ε ≈ 8.85 ⋅ 10 − 12 F / m. A A is the area of the plates., When using capacitors with more than three terminals, follow the instructions included with the capacitor to ensure you connect the wires properly for an AC unit. For some units, two of the terminals may need to be connected by a wire in addition to the AC unit itself. Pro Tip: The average AC capacitor lasts about 20 years., Air Conditioning and Cooling Systems - Where to the brown&Yellow wires of exhaust fan connect to the capacitor? - Hi, I have a Carrier Central air unit. Last night I noticed VERY LITTLE air coming out of register... UNIT was frozen up.Turned it off for the night. SO this morning I looked at the outside unit and It, This article describes the effects of a sting from a bee, wasp, hornet, or yellow jacket. This article describes the effects of a sting from a bee, wasp, hornet, or yellow jacket. ..., Air Conditioning and Cooling Systems - Where to the brown&Yellow wires of exhaust fan connect to the capacitor? - Hi, I have a Carrier Central air unit. Last night I noticed VERY LITTLE air coming out of register... UNIT was frozen up.Turned it off for the night. SO this morning I looked at the outside unit and It, The Turbo 200 has multiple capacitors with the same winding, and it's an industrial-grade permanent capacitor for residential and light commercial HVAC equipment. They are also okay with higher voltages than many other capacitors and have plated brass terminals, which won't rust. The capacitor also gives you the factory microfarad ratings ..., Thanks for answering. There is a second wire (yellow) that goes to the contactor. I got the capacitor that was installed originally. (5 microfarads) It was still working, tech said it was a little weak. The yellow blue sttipe wire goes to the circuit board and plugs into 1 of 4 terminals., The mandatory colors for power wiring in National Electric Codes (NEC) are Green, Bare or Green/Yellow (Yellow Strip or band on Green) for Protective Ground “PG” and White (alternatively Grey) for Neutral Wire. Any other colors expected the above mentioned can be used for Live (Line or Hot) wires., Dayton General Purpose Motor Totally Enclosed Fan Cooled Rigid Base Mount 1 Hp 115 208 230v Ac 5k960 Grainger. I Have A Dayton 5k436j Motor On Lathe Set Up For 115 Volt Curly Terminals T1 T3 T8 Wired Together Then. Dayton General Purpose Motor Open Dripproof Face Mount 1 Hp 725 Nameplate Rpm 115 208 230v Ac 31tr91 119167 00 Grainger., Jun 2, 2023 · Where Do The Wires Go On A Run Capacitor Quora. 35 5 Mfd Titan Pro Dual Round Extended Life Run Capacitor. Cps 5 2 1 Compressor Saver Hard Start Kit Csru1 Jackson Systems. Ac Capacitor Wiring Diagram And Connection Procedure Etechnog. Electric Motor Starting Capacitor Wiring Installation Guide To Air Conditioning Compressor Other Start Boost Or ... , the blue-white 45 ohms is the run winding. from red to blue you get 69+45=114 ohms the total resistance of start+run windings. the 2.5 mfd cap is to be connected to the start winding at red end and to line phase. the blue wire from the run winding also connects to phase line. the white wire connects to mains neutral., Sep 4, 2005 · Air Conditioning and Cooling Systems - Where to the brown&Yellow wires of exhaust fan connect to the capacitor? - Hi, I have a Carrier Central air unit. Last night I noticed VERY LITTLE air coming out of register... UNIT was frozen up.Turned it off for the night. SO this morning I looked at the outside unit and It , Yes, the capacitor has gotten damaged, at least somewhat. How badly damaged, and how irreversible the damage depends on what voltage was applied for how long. A 50 V capacitor can probably take 5 V in reverse for a few seconds, and probably mostly recover when promptly forward biased. The prognosis gets worse at higher voltage and longer time., Dingy yellow pillows are sad to look at and, frankly, disgusting. Don't throw a pillow out if it's not time yet. A quick wash will get it back to its pure white, original state. Di..., Genteq C3355R - The Most Affordable HVAC Capacitor. Besides being one of the most affordable capacitors on the market, the Genteq C335 is also one of the most durable HVAC capacitors you can get. However, this part is only compatible with HVAC systems that run on 370V, and you can't use them on 440V systems., Step 3: Connect Power Wires. The power wires are typically marked as “L” or “Line” and “N” or “Neutral.”. Connect the power wires from your electrical supply to the corresponding terminals on the capacitor. Ensure proper insulation and tight connections to …, Step 3. Connect the red wire, leading to the capacitor, to the start terminal. The black wire, leading to the load side of the contactor, is connected to the run terminal. The white common line is connected in series with an overload switch that protects the compressor from overheating. The overload might be internally located in the compressor., The capacitor may be burnt out or weak, and you'll need to replace it with a new one. PERFECT FIT: The CBB61 5uf 2-Wire 250V Ceiling Fan Capacitor (47x29x18mm) is widely used for ceiling fan, wall fan, stand fan, industrial fan, range hood fan, air exchange fan, water pump, motor, generator, etc.