Limit circuit fault furnace

Dometic Heater shows one flash Air flow / Limit fault. Heater for the air i main area. 339ds Sportmen sprortcoach. ... Dometic furnace, blower comes on but won't ignite. Circuit board led says air flow/limit fault ... Atwood furnace air flow limit fault. When I turn it on the fan works properly but the pilot light doesn't ignite ...

Limit circuit fault furnace. What is a furnace limit switch and why is it important?Switch limit furnace reset rheem ruud manual parts walmart button amana thermostat weather king zeetreby Furnace limit switch for amana 101235-32Limit circuit fault, need second advice (carrier 58mvb).

05 - Heil Furnace Igniter. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter fails, the gas won't continue to be ignited and the furnace may start then stop. To determine if the igniter is faulty, remove the igniter and inspect it for cracks. If the igniter is cracked, replace it.

Power ON Open all manual oil line valves. Close the line switch. Call for Heat Set thermostat (and limit) to call for heat. Thermostat circuit must be closed and power must be coming to black wire from limit circuit. Burner On The ignitor starts, followed 3 seconds later by the motor. (This delay compensates for sluggish start-up of some ACCode 33- Limit Circuit Fault AND high heat only is active; Code 45- Control Circuitry Lockout; Code 41- Blower Motor Fault (cooling mode only) (ventilator, humidifier, dehumidifier, outdoor unit will be turned off) ... wait 30 seconds, then restore power. Reset thermostat. Observe operation of furnace through 1 cooling cycle. If fault code 44 ...The blower below could be the cause of limiting out of the furnace. This is the result of no filter in the furnace or a plugged filter. It requires thorough cleaning by disassembly and cleaning the blower wheel with strong detergent or power wash. The motor (center) should not get water on it. Clean it with a brush.Solution: If the draft blower starts - you hear it hum - but the furnace doesn't ignite, the problem could be caused by a blockage in the vent. This is not super-common, but something to consider if other solutions don't work. 6. The High Limit Switch is Open.Bryant Gas Furnace 395CAV: Troubleshooting Guide Diagnostic of 31 Pressure fault code. Limit Circuit Fault. Furnace Bryant CONDENSING GAS FURNACE 340MAV User's Information. Carrier Bryant Payne HH18HA452 Roll Out Switch. Forum discussion: Product Description of [post_title] below:Furnace shut off with "Limit Switch Lockout" (code 13). Works for 24 hours after a reset, power cycle. ... and then furnace does function throughout the day. If I just power cycle (and don't press the reset switch) I get a limit circuit fault, code 33. ... causing temp limit fault. After replacing the filter, cleaning out the condensate trap ...

The other option you want to try out is replacing the circuit breaker. A broken circuit breaker can lead to minimal power flowing to the outlet. As a result, the wall socket may be delivering less than the necessary 110 volts. ... The Goodman furnace comes with a limit switch that monitors heat exchange temperatures and fuel pressure.Bryant furnace: limit circuit lockout bryant furnaceHave a carrier 48gs-030060301 package, the fault code is 1 flash=fan on Power line carrier channel (plcc) and application of transmission lineCarrier infinity thermal lockout.The Bryant Legacy Plus 90 is a single-stage gas rated furnace with an AFUE rating of 95.5%. The Plus 90 utilizes Bryant's Fan On Plus technology to improve air circulation and fan monitoring. The furnace is made with a low-noise combustion system for silent operation and a high-efficiency air filter cabinet to enhance air quality.Hi, Here is a manual on the furnace,page 8 shows the wiring diagram on the unit.First check for 12 volts to the sail switch,it comes from the limit ... Red light on circuit board is flashing with a 3 second pause. ... a Atwood furnace Model #8531-IV DCLP, the fan comes on for about 20 sec then stops, it is showing a code for air flow limit ...Follow the red to the roll out switch (s). The red wire just makes a loop starting at the board and ending at the board. on the rollout switch, there should be a small button between the wires. It may be red or black. Press that and see if you feel it click. Then retry the furnace.

33 Limit circuit fault The code shows that the flame rollout or limit is open; it also informs that the furnace runs only in high heat mode because of two repetitive low heat limit trips. The blower will operate for four minutes or until the open switch will remake, whichever takes longer.In 2003, we had a new high-end Carrier Infinity Weathermaker furnace installed - Model 58MVP-100-20 (run on propane). 8 years later, in 2011 - while still under warranty (parts and labor) ... On the screen, it says system fault, and under it, it says 33-limit fault. There currently is no heat in the house.Furnace is not heating fault code: limit circuit open or external load on "W" I have reset the furnace, checked the supply air limit switch, checked the filter and cleaned the flame sensor Blower is on, thermostat is turned off, fan on auto. Contractor's Assistant: How old is your furnace? Is the air filter clean? 20 years old, checked last summer, filter is clean My Carrier Performance 96 series furnace (similar to the 59TP6 currently shown on Carrier's website, but I don't have the exact model number in front of me) has been showing codes 13 ("Limit Circuit Lockout") and 33 ("Limit Circuit Fault") intermittently for the last two years, but several repairmen have come and been unable to find anything wrong.

El potrillo mexican restaurant tiptonville menu.

Furnace Fault Code Guide. Interpretation Tips. Repair vs. Replace. Resetting Air Conditioner Thermostat. Steps and Tips. HVAC Fault Codes for Heat Pump Systems. ... such as "33 Limit Circuit Fault" or "42 Inducer Motor Fault," to swiftly identify potential malfunctions and take appropriate action. Repair vs. Replace.This is a good example of why I don't recommend 3M air filters. Temperature went from 116° to 195° after putting the filter in the it's cabinet due to these ...11 Aug 2011 ... If your gas furnace is not heating properly, the problem may be a faulty limit switch. In this video, we'll guide you through everything you ...Given below are the 3 steps needed to reset your Lennox furnace -. Switch off the electrical supply to your Lennox furnace which is present in an electric panel. This will eradicate the risk of any electrical devastations. Turn off the circuit breaker switch tagged "Furnace" or "Heating System". Look at the control panel on your ...CODE: 3-3. RESULT: LIMIT CIRCUIT FAULT FIX: Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13.

In 2003, we had a new high-end Carrier Infinity Weathermaker furnace installed - Model 58MVP-100-20 (run on propane). 8 years later, in 2011 - while still under warranty (parts and labor) ... On the screen, it says system fault, and under it, it says 33-limit fault. There currently is no heat in the house. Why does the 80+ and 90+ gas furnace use different LP kits? Each Inshot burner on a 80+ gas furnace has a fire rate of 25,000 BTU per burner. Each Inshot burner on a 90+ gas furnace has a fire rate of 15,000 BTU per burner. Because of the difference in firing rates the 80+ and 90+ furnaces require different orifices. Have a Payne gas furnace that stopped heating. My digital thermostat went blank and now the furnace only blows air. The red LED light in the furnace is blinking a code--- 3 slow flashes and then 3 fas … read moreThe light indicator on the circuit board is lighting up 1 time every 3 seconds which on the fan motor they have provided a summary chart indicating "Air Flow / Limit Fault" but I can find no limitations to the air flow, it appears to fully flow and does occasionally work. ... i have a 2017 fe29 with the exact same furnace. if you look on ...Pictures: Part of the trouble shooting manual showing the #13 and #33 errors. The limit switch. Old limit switch stuck in the open position. Manual override of the limit switch - NOT RECOMMENDED. Limit switch model. Carrier furnace type. The replacement limit switch. Brand new limit switch.What is the furnace error code limit switch open diagnostic code or whatever it is called?It depends on the furnace brand. Four flashes on a York furnace may...Find the most common problems that can cause a Nordyne Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269 ... Lid & Cover Parts Nordyne Capacitor Parts Nordyne Circuit Board & Timer Parts Nordyne Cleaner & Deodorizer Parts Nordyne Compressor & Sealed System Parts Nordyne Deflector & Chute ...rheem furnace model 801 doesn't fire up - currently showing a fault code of 22 indicating main limit or halc open, but i've reset the 2 limit switches and verified that both show 24v across the termin … read moreThe most common cause of Carrier furnace fault code 13 limit lockout is a dirty or clogged air filter. When the air filter becomes clogged, it restricts air flow to the furnace, causing it …

Recent Lennox high efficiency gas furnace displaying Code E250 Please help : (. ... and the heat seems to be working fine. On the panel it says that E250 means "Limit Switch Circuit Open". The furnace seems to be working OK and the heat is working as well. I have turned the power off, then on again but after the heating cycle it displayed the ...

user_12345a said: Use a meter to see if the limit is stuck open - with power off and furnace is cool, disconnect the wires to the high limit, set meter to ohms and check -> it should read 0 ohms or very close to that. If it's open or reads significant resistance, replace the limit with identical goodman part with same readings.tempstar furnace codes If you're looking for help fixing your tempstar furnace, look no further! ... RESULT: Limit circuit fault. FIX: Loose blower wheel; ... RESULT: Limit circuit lockout. FIX: Control will auto-reset after 3 hours. Refer to status code #4. CODE: ...Yes, most furnaces require a dedicated branch circuit to meet safety standards and prevent overloading. This means that the furnace should have its own circuit breaker in the electrical panel. A dedicated circuit ensures that the furnace receives an adequate power supply without being affected by other appliances or devices on the same circuit.The FP1 thermistor temperature must be below the selected low temperature limit setting for 30 continuous seconds during a compressor run cycle to be recognized as a FP1 fault. JW3 Clipped = 10 deg. Unclipped = 30 deg. The FP1 input is bypassed for the initial 120 seconds of a compressor run cycle. FP1 is set at the factory for one try.Furnace turns on and will ignite then the gas immediately shuts off and the blower remains on. Error code is 33 then changes to 13.1. My 8 year old Trane Model tuh2d120a9v5va furnace is not giving out heat. The service people are all busy due to the recent storms. Through the little glass viewing window I see red and green flashing lights. The red flashes 4 times, the green 3 times, and these overlap. The panel inside says the 4 flashing red means an open limit switch.Steps to Safely Reset Your Concord Furnace. Power Off: Begin by switching off the furnace. You can do this by turning off the switch located on or near the furnace or by flipping the appropriate circuit breaker in your home’s electrical panel. Wait: Allow the furnace to sit without power for a few minutes.58MVC060-F-10114 Parts & Furnace Model Repair Help. Find the right Carrier Furnace Model 58MVC060-F-10114 replacement parts for your repair. Filter results by part category, part title and lawn mower symptoms. You can also view 58MVC060-F-10114 parts diagrams and manuals, watch related videos or review common problems that may help answer your questions to get started on fixing your Furnace model.It seems to function fine in all modes HP high/low and furnace low. only problem seems to be a high furnace heat call and then only after 15-30 min of operation. Reply Page 1 of 2 1 2 Last

Oregon state football radio live stream.

Servatii pastry shop and deli western hills.

Troubleshooting the Open Limit Fault - YouTube. Nortek Global HVAC. 15.1K subscribers. Subscribed. 57. 15K views 6 years ago. Learn how to troubleshoot an open limit fault on a …In this episode of Repair and Replace, Vance shows how to replace the high limit switch in a gas furnace. The limit switch is a safety switch that monitors t...* Update: I replaced the filter and that fixed the problem. Hope this helps and saves you some money.Here is short video showing how to read the blinking e...With the fault you are seeing it could be low DC voltage, faulty sail switch, limit switch or circuit board. Make sure you have good DC battery voltage, if the voltage is below 12 volts the fan can slow down and not spin fast enough to close the sail switch.Improper pressures can result in the furnace not working. Be aware that there is a difference in manifold pressures from a propane furnace to a natural gas furnace. The operation of the furnaces is the same but the delivery pressures differ because of the properties of the different gases. 2. Furnace Circuit Boards and Control ModulesTransformer (24v) behind control center provides low-voltage power to furnace control center and thermostat. Limit switch (manual reset) on 58MVP only. MODELS 58MXA AND 58MCA FURNACES (UPFLOW POSITION) MODEL 58MVP FURNACE (UPFLOW POSITION) IMPORTANT FACTS. Your gas furnace uses air from outside the home for combustion and venting.Gas and Oil Home Heating Furnaces - Goodman Furnace Open High Limit (code: 4 blinking lights) - Hello, I have a Goodman Furnace, model GDH80703AXAC, it was installed a little under a year ago. It worked fine for the first year and fine so far for this year. Until about 2 days ago. The burners went out, and when ICode 41 - Blower Motor Fault Furnace generated Critical Malfunctions: Code 15 - Blower Motor Lockout Code 41 - Blower Motor Fault (317) 555-1234 FAN: AUTO CALL TECHNICIAN OUTSIDE: 94 ... Code 33 - Limit Circuit Fault AND high heat only is active Code 45 - Control Circuitry Lockout Code 41 - Blower Motor Fault ((-A) models only)Carrier Furnace Limit Circuit Lockout [ 1 Answers ] My Carrier Furnace is continuously blowing and the heat doesn't work. The code was first, Limit Circuit Fault, tnen after changing the filter, it went to Limit Circuit Lockout -- and it is still blowing cold air. (Yikes!! It got down to 10 degrees outside)Frigidaire Furnace Troubleshooting & Repair | Repair Clinic. Price Match Guarantee. Order by 1:00 a.m., and we'll ship the same day. 365-Day Return Policy. Choose Product. 02. Identify Problem. 03. Find Solutions. ….

If air flow is restricted the heat is not dissipated quickly enough, and the high limit switch will kick in as the furnace overheats. Make sure the filter is clean, and the appropriate density for your furnace. If a different filter does not fix the issue, it may be caused by an under powered blower motor. –I have a 2019 92% 80K BTU Heil gas furnace that started giving me a Code 4 'Limit Circuit Fault' for the past couple of weeks. The furnace will run for about 5 minutes, cycle itself off, and then turn back on until it reaches the set temperature. I called a service tech last week who thinks it could be undersized venting.Originally Posted by Jayco31fs. Check your run start capacitor, as it turns on the fan, if it's bad it will trip your high limit switch due to fan not running. No run start capacitor on RV Furnace FAN. RV A/C Unit yes. High Limit Switch ONLY trips due to HIGH Temp -----exceeding the switch set point.In 2003, we had a new high-end Carrier Infinity Weathermaker furnace installed - Model 58MVP-100-20 (run on propane). 8 years later, in 2011 - while still under warranty (parts and labor) ... On the screen, it says system fault, and under it, it says 33-limit fault. There currently is no heat in the house.I have a Nordyne G6RA mid efficiency furnace that was installed about 6 years ago. The problem is that the furnace continuelly kicks out on supplu air hi limit after about 5 min. The furnace then will … read moreThe Bryant furnace code 33 indicates that a limit or flame rollout switch is open. This could occur due to Overheating in the furnace caused by insufficient airflow or the furnace operating only in high-heat mode. The blower will remain active for 4 minutes or until the switch resets, whichever duration is greater.rheem furnace model 801 doesn't fire up - currently showing a fault code of 22 indicating main limit or halc open, but i've reset the 2 limit switches and verified that both show 24v across the termin … read moreStep 2: Locate the Heating Duct. To locate the limit switch, you must first locate the heating ducts on your furnace. The ducts are typically located in the home's basement or utility closet. The panel holding the limit switch is located underneath the duct.High Limit Circuit Open Okay, so I haven't had a chance to try to the power down like Tim mentioned. I will do that tonight. I was able to find the fault codes and 4 flashes says that the High Limit Circuit is Open. Is there a switch or breaker that needs to be flipped or is there a fuse that needs to be replaced in order to close the circuit?LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset. Limit circuit fault furnace, Code 33 on Carrier and Bryant furnaces is caused by a lack of airflow. If the issue is not resolved in time, it may develop to code 13, caused by safety lockout. Code 33 is a Limit Circuit Fault code. This means that the flame rollout switch is open. If the high limit or flame rollout switch is open, you will experience error code 13., 13,008. Post Likes. Originally Posted by The Gaffer. Have a customer with a ICP high efficiency furnace, throwing a 4 flashing light code, limit switch open. Here is what I have done so far (most as part of general service): Changed 2 x limit switch. Changed Pressure switch. Changed ignitor. Changed flame sensor., Atwood furnace fault codes: Atwood is a famous company that manufactures these furnaces. ... this indicates a hard lockout and a failure with the internal circuit board. A flashing light with a single flash repeated after a 3 second pause - this indicates a problem with the airflow or the limit switch, and it can be reset after the fault is ..., The circuit board indicated a no.1 fault (Air flow/Limit Fault). I dismantled the furnace blower (from the outside, without removing the furnace) and discovered that the problem was the sail switch was improperly placed, and rubbing against the outside housing (sticking, in other words). I fixed that, and all is good now., Forum Rules. Hi all! I recently noticed my Tempstar furnace acting up. After attempting some self-diagnosis, I had a company come out. As the furnace was giving a 4 flash (Limit Circuit Fault), they recommended changing out the pressure switch and high limit, as they were the easiest to try. This was done, but the problem persists., The yellow light indicates the burner flame mode, while the green light indicates the fan mode. The codes can help you troubleshoot and fix some common problems with your furnace, such as a defective gas valve solenoid or an open circuit. Carrier furnace light codes are also in different colors of fluorescent tubes to help identify the system ..., Single Stage Multi Position Furnace Service Manual the main limit is open, the combustion blower, − Stuck open or leaky gas valve. 4 LIMIT CIRCUIT FAULT − Indicates the limit, flame rollout switch is open. Blower and inducer will run, Status Code 13 - Limit Circuit Lockout. 16. Status Code 14 - Ignition Lockout. 17. ... Limit Circuit Fault. 26. Status Code 34 - Ignition-Proving Fault. 28. ... DIRECT VENT 4-WAY MULTIPOISE MODULATING CONDENSING GAS FURNACE WITH PERFECT SENSE PERFECT HUMIDITY. Brand: Bryant ..., Has setting limits not worked? Despite your efforts, are your boundaries often ignored? It’s frustrating, to Has setting limits not worked? Despite your efforts, are your boundarie..., CODE: 33. PROBLEM: LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires ..., From https://www.justanswer.com/ythiJustAnswer Customer: My carrier furnace is blinking code 13: limit circuit lockout.JustAnswer Customer: if i flip the pow..., Atwood furnace ignition lockout fault happens due to 3 possible reasons. Let’s learn the reasons in detail to solve the problem efficiently. 1. Faulty Flame Sensor. When you face a furnace lockout, check the condition of the flame sensor. This is the first thing you will need to do without fail. The faulty flame sensor is one of the common ..., Furnace turns on and will ignite then the gas immediately shuts off and the blower remains on. Error code is 33 then changes to 13., Furnace Fault Code Guide. Interpretation Tips. Repair vs. Replace. Resetting Air Conditioner Thermostat. Steps and Tips. HVAC Fault Codes for Heat Pump Systems. ... such as "33 Limit Circuit Fault" or "42 Inducer Motor Fault," to swiftly identify potential malfunctions and take appropriate action. Repair vs. Replace., tempstar furnace codes If you're looking for help fixing your tempstar furnace, look no further! ... RESULT: Limit circuit fault. FIX: Loose blower wheel; ... RESULT: Limit circuit lockout. FIX: Control will auto-reset after 3 hours. Refer to status code #4. CODE: ..., If we find a limit open, we will remove the limit, note the open rating (May be 180 to 210). Stick a metal probe thermometer in the chamber where we removed limit, call for heat and see if chamber is getting hotter than the rating on limit. If not we have a bad limit and it will need to be replaced. If it is getting too hot we have to determine ..., I show up and find many instances of 33- Limit Fault, and 42- Inducer Motor Fault. ... Code 33 is a limit circuit fault. ... I had a similar fault code 33 on the very same furnace with 80K and what fixed the problem was checking the manifold pressure of both low and high fire as the original installers never bothered to do so .Customer liked to ..., Press and hold the red "Reset" button in the center of the rollout limit switch component. Hold the button for one to two seconds before releasing it. Founded in 1982, Goodman Manufacturing is an American company that produces heating and air conditioning equipment for residential and commercial customers. Goodman residential furnaces contain ..., Atwood furnace fault lockout ignitionLimit switch open hvac 4d99 b01c 18b1 furnace Furnace trane bryant device condensingSingle stage furnace limit circuit. Carrier furnace[gas furnace, 58cva070] tripping on limit circuit lockout : hvacadvice Carrier fault circuit advice limit second needAtwood furnace schematics. Check Details Limit circuit ..., Test - Check for proper airflow and use a multimeter or observe the flame sensor light. Reset - Gently press each arm of the limit switch till you hear a click. Turn On Power - T urn back on the power and let the furnace go to auto mode. Refer to the user manual if you're stuck., When the plenum hits that temperature, the limit switch lets the air handler know that it can run, delivering the warm air that you want into your home. The limit switch is basically a safety device as well. When the plenum temperature gets too hot, the limit switch shuts off the supply of gas to the burners. By shutting off the gas supply, the ..., CODE: Four LED flashes PROBLEM: Limit circuit fault: either a limit or flame rollout is open FIX: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower CODE: Five LED flashes PROBLEM: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized FIX: Check for a ... , On Carrier, Bryant and Payne furnaces, the lack of airflow will cause an error 33, and sometimes lead to error 13 due to safety lockout. Error 33 is a Limit Circuit Fault. It means that the high limit or flame rollout switch is open. This can lead to error code 13, Limit Circuit Lockout., location on the burner, furnace or wall. The location must not exceed the ambient temperature limit, 140°F. ... Call for heat Set thermostat (or limit) to call for heat. Thermostat circuit must be closed and power coming to black wire from limit circuit. Self-test 2 The amber LED turns on. For the first 3 to 4 seconds, the control per- ..., Step 4. Return to the circuit breaker box. Move the furnace's circuit breaker switch into the "On" position. Advertisement. Founded in 1900, Coleman Heating and Air Conditioning has been manufacturing HVAC equipment for residential customers for over 100 years., When the draft inducer is working as it should, the pressure switch then completely closes the circuit (turns on). Issues. When there is an issue with the draft inducer motor, the pressure switch will then open or turn off. The furnace then shuts down to prevent ignition since there could be a buildup of those dangerous gases., When the draft inducer is working as it should, the pressure switch then completely closes the circuit (turns on). Issues. When there is an issue with the draft inducer motor, the pressure switch will then open or turn off. The furnace then shuts down to prevent ignition since there could be a buildup of those dangerous gases., CODE: Four LED flashes PROBLEM: Limit circuit fault: either a limit or flame rollout is open FIX: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower CODE: Five LED flashes PROBLEM: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized FIX: Check for a ..., Method 1. To reset the system from the space, turn the "Mode" selection switch at the thermostat to the "Off" position. After approximately 30 seconds, turn the "Mode" selection switch to the desired mode, ie...Heat, Cool, or Auto. Method 2. To reset the system at the unit, cycle the unit power by turning the disconnect switch "Off" and then "On"., Kenmore Capacitor Parts Kenmore Chassis Parts Kenmore Circuit Board & Timer Parts Kenmore Compressor & Sealed System Parts Kenmore Deflector & Chute Parts Kenmore Diode, ... Shop by Popular Kenmore Furnace Models. 867.740290 867.740291 867.740293 867.741010 867.741090 867.741434., The blower below could be the cause of limiting out of the furnace. This is the result of no filter in the furnace or a plugged filter. It requires thorough cleaning by disassembly and cleaning the blower wheel with strong detergent or power wash. The motor (center) should not get water on it. Clean it with a brush., LIMIT CIRCUIT FAULT – Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset., Thanks in advance. Fojo. HVACDave said: Hi Mudtruck, To determine if it is code 13 or 31. The first digit is the number of short flashes, the second digit is the number of long flashes. 13 is limit circuit lockout, in which case your furnace would try and restart after 3 hours. The limit circuit is there to protect the furnace from overheating ...